MPPT compatibility and regulation

With a Storage MPPT 500–600W (12V) inverter specifically for wind turbines, is a wind regulator necessary?
The presence of a Storage inverter does not automatically replace wind regulation. If the inverter is powered by a 12 V battery, the wind turbine must charge this battery through a compatible wind regulator, with the intended braking or load shedding. A direct connection is only possible if the inverter's manual explicitly indicates an input suitable for this generator; a solar PV input is not suitable. Learn more: Hybrid wind regulators.
Why use an MPPT regulator?
The MPPT optimizes production by adapting to variations in irradiation and temperature, improves charging (profiles adapted to battery chemistry), and contributes to the longevity of the system. See our selection: MPPT regulators.
Basic diagram: solar panel + regulator + battery + 230V converter?
1) Panel → PV input of the regulator (MPPT/PWM). 2) "BAT" output of the regulator → battery (12/24/48 V). 3) 230 V converter connected to the battery (never to the PV input). 4) Protect each connection with a fuse/circuit breaker. Detailed diagrams: download.
Does an MPPT controller extend the life of batteries?
A solar MPPT regulator can help preserve the battery if it applies a charging profile adapted to its chemistry and limits. The functions for cutting off against deep discharge depend on the regulator, its wiring, and any BMS; they are not guaranteed by the mere presence of the MPPT. Apply equalization only if the battery manufacturer authorizes it. Resources: Gel/AGM · LiFePO₄.
Is a 48V wind regulator with automatic braking or MPPT 800W compatible with my generator?
Compatibility depends on the type of generator output, its voltage and current range, its power, the battery system voltage, and the load shedding device. The mention of 48V or 800W is not sufficient. Compare the exact specifications and verify that the regulator is designed for the wind turbine or generator concerned. A solar MPPT is not suitable. Learn more: Wind regulators.

Dump load and braking

Can a wind turbine be manually stopped in case of a storm?
Yes, only with the device and procedure intended for the model: braking switch, controlled short-circuiting, regulator command, lowering the mast, or another solution indicated by the manufacturer. Do not handle the wind turbine during a storm and do not arbitrarily disconnect its load. Check the compatibility of any stop switch with the voltage, current, and type of generator. Learn more: 3-Phase AC Stop Switch/Selector for Wind Turbine Control.
What happens when the batteries are full in a wind turbine installation?
The regulator must limit the charge and direct the excess to the dump load or the designated device. This charge maintains an electrical effort on the generator and contributes to braking. Do not simply disconnect the battery from a running wind turbine. The regulator, dump load, and thresholds must be compatible with the system's voltage and power. Learn more: Discharge resistors - dump-load.
Domestic wind turbine: can I replace the dump load with the water heater's resistor to dissipate the excess?
No. The dump load of a wind turbine regulator is sized and controlled to brake the generator; the tank's resistor is not a safe equivalent (thermostat that opens the circuit, anti-boil safety, etc.). Keep a dedicated dump load and, if you want to heat water, control the tank separately on the 230 V side. References: hybrid wind turbine regulators and dedicated dump loads. The final compatibility must be verified on the exact references: nominal voltage, input or output type, allowable power, regulation, and protections.
Is an external regulator / dump load needed for a generator + 2000W inverter kit used in hydro?
A hydro injection without a battery is only conceivable if the inverter is explicitly compatible with the generator and its continuous operation. Check its manual for integrated rectification, regulation, load shedding, and protection functions in case of network loss. An external device may still be necessary; do not infer its absence from the mention "special wind turbine." For battery charging, use regulation compatible with the hydro application. Resources: 230 V injection inverters · wind turbine regulators.
Sydney 2000W 48V Kit: dump load included?
Check the exact contents of the Sydney 2000 W 48 V kit on its datasheet and in the manual of the selected option. The dump load resistor may be integrated or separate depending on the equipment; its presence and operation in case of network loss should not be assumed. Use only the architecture provided for the kit. Resources: product datasheet.
What is the difference between a 12V, 24V, and 48V dump load resistor?
The nominal voltage and the allowable dissipation power. At 48 V, the power to be dissipated is higher for the same current. Select a model compatible with your regulator and your setup: resistors.
48V / 3000W wind turbine regulator without dump load connection: normal?
The absence of an external resistor terminal may correspond to integrated dissipation, but it is not sufficient to confirm it. Consult the exact diagram of the 48 V / 3000 W regulator. Do not add a resistor to unplanned terminals and do not use the system without the prescribed protection device. Learn more: Discharge resistors - dump-load.
What are the purposes of the wind turbine regulator and the dump load resistor?
The wind turbine regulator adapts the production to the battery charge and, depending on the model, rectifies the three-phase AC. When the battery can no longer absorb energy, the system must maintain an electrical load on the generator. The dump load resistor dissipates the excess and contributes to braking. It must be compatible with the voltage, power, and regulator. Do not replace it with a water heater resistor and do not operate a wind turbine without the device specified in its manual. Learn more: Discharge resistors - dump-load.

Rectification

Generator ref. 15373 on rectifier bridge + grid-tie inverter without batteries?
This setup is only conceivable with an inverter explicitly compatible with the 15373 generator and with a DC input after rectification. An inverter designed for three-phase AC does not connect at the same point. In the absence of confirmed compatibility, an architecture with a wind turbine regulator and batteries must also be validated on the exact references. Learn more: Wind turbine generator.
I want to keep my three-phase rectifier and power a DC inverter like the Ginlong GCI-2K: do you offer this type of inverter?
We do not identify in this FAQ a wind turbine inverter with a DC input that can be offered as a direct replacement for the Ginlong GCI-2K. Another architecture may use the generator's three-phase AC output or go through regulation and batteries, only after validation of all references. Do not remove the rectifier or modify the wiring without an approved diagram. Resources: 230 V wind turbine inverters · wind turbine regulators.
100A rectifier bridge for 1000W / 24V three-phase generator?
For a 24 V / 1000 W generator, the choice of the diode bridge mainly depends on the allowable continuous current and thermal margin. Refer to the range: Diode bridges.
What is the difference between a single-phase and a three-phase diode bridge?
Single-phase for 1-phase source (L–N); three-phase for 3-wire AC source. Choose according to the generator: single-phase bridge • three-phase bridge.
What are the steps to integrate a diode bridge into a wind turbine installation?
The diagram depends on the type of regulator input. A diode bridge rectifies the three AC phases to a DC output, but it should only be added if the regulation accepts this output and does not already perform the rectification. Then, compatible regulation, load shedding, and protections are needed before charging the batteries. Follow the exact reference diagram. Resources: wiring diagrams.
Does a rectifier diode bridge replace a regulator or charge controller?
No. The diode bridge only performs AC/DC rectification. Charging a battery requires suitable regulation and, for a wind turbine, the planned braking or load shedding management. Deep discharge protection depends on the regulator, inverter, BMS, and wiring; it is not provided by the bridge. Resources: wind regulators · hybrid regulators.

Wind Regulators

Can a 12V wind regulator be used with a hydro generator?
Only if the manufacturer confirms that the regulator accepts the type of generator, voltage, current, continuous operation, and load shedding mode of the hydro generator. The mere mention of 12V is not enough. In hydro, the source can operate for a long time at stable power; cooling and excess management must be suitable. Have the association validated by the manufacturer or original seller. Learn more: Wind regulators.
Are battery-charging wind turbines always delivered with a lithium and lead compatible regulator?
No, it should not be assumed. The product content and accepted battery technologies depend on the regulator's reference. Check the datasheet for the presence of the regulator, 12V, 24V, or 48V voltage, compatible charge profiles, BMS thresholds for lithium, and the braking or load shedding device. Learn more: Wind regulators.
5-blade wind turbine 48V / 2kW: external resistance 1200W on the regulator?
No, do not add an external resistance if the model's regulator already integrates its own dissipation. Learn more: ERDF self-consumption wind kits 230V/230V.
Is there a 12V wind regulator without braking or limitation?
No, a wind system should not operate entirely without protection. When the battery is full, disconnected, or no longer accepts charge, the produced energy must be managed to avoid excessive speed and voltage increase of the generator. Depending on the equipment, this protection can take the form of electrical braking, load shedding to a resistance, or a limitation integrated into the regulator. Do not connect a wind generator directly to a battery without a suitable wind regulator. Learn more: Wind regulators.
Is a regulator needed if I use a special wind inverter to inject into 230V?
A separate regulator is not necessary only if the inverter is explicitly designed for wind, accepts the exact output of the generator, and integrates the rectification, control, and protection functions provided by the manufacturer. For a battery charging installation, a suitable wind regulator remains mandatory. Always check the voltage, power, output type, and presence of the required load shedding device. Learn more: Wind grid-tie inverters 230V.
I received a 30A regulator while the photo indicated 10A: can I use it?
A maximum current of 30 A does not mean that the regulator will impose 30 A on the wind turbine or battery. It indicates the maximum current the device can accept. The model can be used only if its nominal voltage, regulation type, connection, and compatibility with the wind turbine and battery match the ordered reference. In case of labeling or casing differences, check the complete reference before installation. Final compatibility must be verified on the exact references: nominal voltage, input or output type, admissible power, regulation, and protections. Learn more: Wind regulators.
I have an Aerogen 6 wind turbine and am looking for a suitable charge regulator. Do you have a model?
We do not have a regulator compatible with Aerogen 6 (specific output). Please consult the manufacturer or a dedicated reseller. For technology comparison, see our wind regulators (not compatible with Aerogen 6).
I use an Aquagen4 hydrogenerator in 12V: do you have a compatible regulator or discharge resistance?
Our regulators are designed for 3-wire three-phase inputs and are not suitable for the Aquagen4 (specific single-phase output). We recommend contacting the manufacturer or a dedicated reseller for a suitable regulation/load shedding unit (type "TB Unit"). For comparison of regulation technologies, see: wind regulators.
I want a 48V low-speed wind turbine with direct injection inverter: is a regulator needed?
A Low-Speed wind turbine intended for battery charging must be used with compatible regulation, then suitable battery banks and an inverter. Do not assume that a direct injection inverter will accept this generator. Check the exact reference and operating mode indicated on its datasheet. Learn more: Isolated site wind turbine kits.
Should the battery remain connected to the wind regulator during operation?
Yes. In a battery charging installation, the wind regulator must remain connected to a compatible battery with the same nominal voltage. During commissioning, generally connect the battery to the regulator first, then the wind turbine to the regulator, according to the model's manual. An absent, disconnected, BMS-protected, or improperly connected battery can disrupt regulation, prevent charging, and compromise braking or load shedding management. Learn more: Wind regulators.
Does the dump load resistor have a connection polarity?
A passive two-wire dump load resistor generally does not have polarity: the two wires can be connected in either direction. However, it must be compatible with the system's voltage and power, and then connected only to the designated terminals on the wind regulator or inverter. Install it in a ventilated location, as it can heat up significantly during load shedding. Learn more: Discharge resistors - dump-load.
Does the wind regulator protect the battery against overcharging?
A compatible regulator limits the charge according to the thresholds set for the battery and manages wind energy according to its architecture: braking, load shedding, or other devices. The charge profile, maximum current, and any BMS must be checked. It does not alone guarantee the lifespan of the battery bank. Learn more: ERDF self-consumption wind turbine kits 230V/230V.
Is the 48V 800W hybrid regulator reference 15067 delivered with a discharge resistor?
No. Reference 15067 is not delivered with an external discharge resistor, as it already has its own dissipation system. A general manual is provided with the product, but we do not have additional detailed technical documentation. Do not add an external resistor if the regulator's diagram does not provide for it. The exact content may vary depending on the reference or option selected; check the list published on the product sheet before ordering. Learn more: 48v / 800W wind-solar hybrid MPPT regulator.
Are 24V vertical wind turbines delivered with a charge regulator?
The content depends on the reference and option chosen. Check the datasheet to see if the 24V regulator is included, its admissible power, its charge profiles, and the required braking or load shedding device. Do not deduce the content of one model from another vertical wind turbine. Resources: 24V models · wind regulators.
My LVM6TB regulation burned out. What regulator do you recommend for an ATMB D400 marine wind turbine (12V or 24V)?
Do not choose a replacement for the LVM6TB based solely on the 12V or 24V voltage. Have the ATMB D400 manufacturer confirm the type of output, electrical limits, regulation, and load shedding required. A hybrid regulator or a three-phase switch can only be used if its compatibility with this wind turbine is explicitly validated. Resources: hybrid wind regulators · 3-phase AC switch.
Inverter 24 / 48V: does it act as a regulator?
No. An injection inverter is not a battery charge regulator. Learn more: Wind network injection inverters 230V.
Can multiple solar panels be connected to a single regulator?
Yes, if the sum of the currents (in parallel mode) and the voltage (in series mode) remain within the regulator's limits. Otherwise, use multiple MPPT inputs or additional regulators. See MPPT. The final compatibility must be verified on the exact references: nominal voltage, type of input or output, admissible power, regulation, and protections.
Why do I feel strong braking when I spin a 2000W wind turbine?
Marked braking can result from electrical load, a braking device, the generator's resisting torque, or a mechanical problem. The nominal power of 2000W does not allow determining the cause. Do not force the drive with a drill; check without power and according to the manual, then have the equipment checked if the behavior is unusual. Learn more: ERDF self-consumption wind turbine kits 230V/230V.
Why is there no photo or dedicated datasheet for the i-1500 / 24V horizontal wind turbine regulator?
The functions and content of the regulator associated with the i-1500 / 24 V must be checked on the kit sheet and the provided manual. Resemblance to a standard regulator does not confirm its wiring or protections. If a photo or dedicated sheet is missing, request the exact reference before considering a replacement. Resources: wind turbine regulators.
Why is a wind charge regulator indispensable?
It secures the battery and the wind turbine (brake/dump-load), extends the lifespan of the park, and stabilizes production. Learn more: Info - wind turbines.
Why must a "battery charging" wind turbine be connected to a battery via a regulator?
On a battery charging wind turbine, the regulator needs a battery permanently connected to stabilize the charge and control production. Without a battery/regulator, the wind turbine performs poorly (or not at all). Learn more: Wind turbine kits for isolated sites.
Do you offer a regulator or a 220V DC on-grid inverter of 5 to 6kW?
No. We do not currently sell a grid-tie regulator or inverter covering a nominal input of around 220 V DC, a range up to 300 V DC, and a power of 5 to 6 kW. For an installation of this power and voltage, contact the generator's manufacturer or seller to identify the intended conversion cabinet, then have the connection validated by a specialized electrician. Learn more: Grid-tie inverters.
Can I precisely set 52.3V on the 48V / 800W regulator (photo)?
This model does not allow for a tenth of a volt adjustment for 52.3 V; it applies a standard 48 V profile. For fine-tuning, opt for a more configurable regulator (e.g., advanced range): wind turbine regulators. Final compatibility must be checked on exact references: nominal voltage, input or output type, allowable power, regulation, and protections.
Can I use a 12V panel without a charge regulator?
Not recommended. Without regulation, the battery can be overcharged and damaged. Always install a regulator (PWM or MPPT) between the panel and battery. See solar regulators. Final compatibility must be checked on exact references: nominal voltage, input or output type, allowable power, regulation, and protections.
What is a wind charge regulator?
A wind turbine regulator manages the charge of a compatible battery park and the braking or dump functions provided by the system. Depending on the model, it can also rectify the three-phase AC output. Protection against deep discharge depends on the architecture and is not systematic. Resources: wind turbine regulators.
What should I do if my three-phase generator exceeds the regulator's allowable voltage?
Do not use the setup beyond the allowable input voltage. The choice of a speed limitation, different transmission, or suitable controller must be validated according to the generator's characteristics and protections. Do not modify the mechanics or braking to bypass an electrical limit without the manufacturer's validation. Learn more: Wind turbine regulators.
What does the wind turbine regulator do when the batteries are full?
When the batteries reach their maximum charge level, the regulator must limit or divert the excess energy according to its operation: electrical braking, diversion to a resistor, or safety mode. This management protects the battery and limits the rise in voltage or speed of the generator. Use only the diversion resistor and scheme intended for the system's voltage and power. Learn more: Wind turbine regulators.
What is the role of a regulator in a chain with a 230V converter?
The regulator controls the battery charge. The compatible converter is then powered by the battery park to provide 230 V AC. It should not be connected to the "LOAD" output of a small controller unless explicitly authorized by its manual. Protection against deep discharge must be checked on the selected devices and wiring. Learn more: Wind turbine regulators.
Which charge regulator do you recommend for a 48V / 600W wind turbine?
Reference 15573, announced for 48 V and up to 800 W in this FAQ, can be considered for a 600 W wind turbine, without a guarantee of compatibility on these values alone. Check the generator's output, maximum open-circuit voltage, current, battery profiles, and required braking or diversion on the exact sheets. Resources: ref. 15573.
Which regulator is suitable for the Sydney 48V 800W wind turbine?
A 48 V regulation must be chosen according to the exact characteristics of the Sydney 800 W and the battery. The reference 90553 cited in the source must be confirmed on the datasheet and the manual; the nominal voltage alone is not enough. Also check the load shedding, charge thresholds, and protections. Resources: see here.
Which regulator to use with a 48V hydro turbine?
A 48 V hydro turbine requires a regulator explicitly compatible with its output type, voltage and current range, continuous power, and load shedding device. Do not rely on a generic AC value per phase. Have the association confirmed by the hydro turbine manufacturer. Resources: wind turbine regulators.
Which regulator to use for a small 12V three-phase wind generator of about 80W?
For a small three-phase generator intended to charge a 12 V battery, the 12V / 300W wind turbine regulator, reference 10297, may be a solution to consider. The 80 W power remains below its stated nominal power, but this is not enough to confirm compatibility. Before connecting, check the maximum allowable input voltage, the generator's three-phase output type, the battery used, and the braking or protection functions provided by the regulator. An open-circuit voltage that can reach 80 V must notably remain within the limits explicitly indicated on the product datasheet. Learn more: 12v / 300W Wind Turbine Regulator.
24V / 3000W wind turbine regulator: datasheet?
The available information is what is published on the product datasheet. When no additional document is offered, Le Comptoir Éolien cannot provide an unpublished manual, curve, or certificate. Check the datasheet of the concerned reference. Learn more: Wiring diagrams - solar and wind.
48V programmable wind turbine regulator (absorption + floating)?
No, we do not offer a programmable wind turbine regulator that allows setting the absorption and floating voltages. Learn more: Wind turbine regulators.
What is the maximum voltage a 48V / 5000W hybrid wind turbine regulator can accept?
The maximum voltage depends on the exact reference and should not be inferred from the mere mention of 48V / 5000W. Respect the AC or DC input limit published by the manufacturer, with an appropriate margin for generator surges. Never exceed the value on the datasheet or manual. In the absence of confirmed data, do not make the connection and request validation from the seller or manufacturer. Learn more: Wind turbine regulators.

Need advice on a reference?

Specify the relevant references and the characteristics of your installation to customer service.

Your legal guarantee rights

Your legal guarantee rights

europa.eu/youreurope/citizens/consumers/shopping/guarantees/index_en.htm