FAQ · Wind and Solar
Hybrid: regulation and kits
Dedicated or mixed regulators, voltages, input limits, conversion, load shedding, and kit extension.

Choose a question to display its answer. For any compatibility or electrical intervention, check the manual of each equipment and the complete characteristics of the installation.
Inputs, voltages, and electrical limits
400W wind turbine + a 400W solar panel on my 12 / 24V 600W hybrid regulator: compatible?
The 600 W limit must be interpreted according to the manual: it may refer to an input, total power, or a specific condition. Check wind and solar limits, voltages, currents, and the battery bank separately. Do not claim that exactly 200 W remains for solar without model confirmation. Do not connect 400 W + 400 W until compatibility is established. Learn more: Hybrid wind + solar kits.
Hybrid MPPT inverter 1000W / 36V: why 45V max in operational range?
Different voltage ranges should not be interpreted from a supposed manufacturer explanation. Check the reference and version of the manual: absolute maximum voltage, operating range, and MPPT range may indicate distinct limits. In case of contradiction between 39–62 V and 32–45 V, seek confirmation before connection and do not exceed any confirmed limit. Learn more: Hybrid wind + solar kits.
What to do if my 600W hybrid regulator is too limited (wind + solar)?
First check the separate and combined limits of the regulator reference. It may be necessary to reduce a source, choose a compatible controller with higher capacity, or separate the regulations according to a validated scheme. A 200 W panel limit should not be applied without knowing the exact characteristics. Resources: Hybrid wind regulators.
Mixed solar + wind charge controller in 12V (1000–1500W): do you have the same model?
Please specify the desired reference. Depending on the power, either a dedicated wind regulator (and a separate solar MPPT) or a hybrid controller will be used. Compare our options here: wind regulators and solar regulators.
48V solar system + small 24V DC wind turbine: 24V→48V / AC converter compatible?
There is no simple and reliable solution to convert this type of 24 V DC wind turbine to your 48 V bus or the main converter AC input. The safest option is to use a native 48 V wind turbine connected to the bank via a 48 V regulator. See 48 V wind turbines and 48 V regulators. Final compatibility must be checked on exact references: nominal voltage, input or output type, allowable power, regulation, and protections.
Air-WPR 24V 800W with 24V 1000W inverter: compatible?
The combination of Air-WPR 24 V / 800 W and 24 V / 1000 W inverter must be explicitly confirmed. The presence of three AC wires is not sufficient. If the set is validated for direct injection, follow its rectification, control, braking, and load-shedding scheme; do not add a solar MPPT. Also check protections and network connection. Resources: 230 V wind grid-tie inverters · wiring diagrams.
What are the input limits of the concerned 24V / 48V 1000W hybrid wind-solar controller?
The exact reference of the controller must be identified before retaining the values of 1000 W PV, 80 V, and 1200 W wind cited in the source. Check on its datasheet the specific limits for each input, the MPPT range, the maximum open-circuit voltage, currents, and the bank voltage. The mention of 24/48 V and 1000 W is not enough to confirm these characteristics. Learn more: Hybrid wind regulators.
Can a two-wire wind turbine be connected to a hybrid wind-solar regulator?
The presence of only two wires does not confirm compatibility. Depending on the model, the output may be single-phase, rectified to direct current, or associated with internal regulation. The exact reference, current type, voltage, and power must be known before any connection. Contact the wind turbine seller or manufacturer and do not connect it randomly to a three-phase or solar input. Learn more: Hybrid wind regulators.
Can a 12V / 400W wind turbine and a 12V / 200W solar panel be connected to a 12 / 24V / 600W hybrid regulator?
Only if the regulator datasheet indicates that the 600W limit indeed applies to the sum of both inputs and that the voltage and current ranges of each source are respected. The simple addition of 400W + 200W is not enough to confirm compatibility. Use the wind input for the turbine, the solar input for the panel, and a battery bank at the selected nominal voltage. Also check load-shedding and charge thresholds. Learn more: Hybrid wind regulators.
Wind turbine 15006 + hybrid regulator 17009 + 12V / 100W panel: compatible?
Check the datasheets for references 15006 and 17009 for the type of wind turbine output, the limits of each input, the battery bank voltage, and the charging profiles. A panel rated 12 V / 100 W must also comply with the open-circuit voltage and current limits of the controller. Compatibility cannot be deduced from these mentions alone. Resources: 12 V hybrid regulators.
Is a transformer needed to charge 24V batteries with a three-wire three-phase wind turbine?
No. The three wires generally correspond to the three AC phases of the generator, without positive or negative polarity. To charge a 24 V battery bank, use a 24 V wind regulator with suitable rectification, not a simple transformer. For a wind turbine up to about 650 W, the 24 V / 650 W wind-solar hybrid regulator can be a reference to consider. For higher power, a 24 V regulation with greater capacity, such as the 15265 reference rated for 1500 W, may be necessary. Compatibility must be checked with the actual power, open-circuit voltage, generator curve, and battery. A wind turbine purchased from another seller should not be connected without knowing its exact characteristics. A three-wire generator generally delivers three-phase AC: these conductors have no positive or negative polarity. The connection must follow the instructions of the compatible regulator, rectifier, or inverter. Learn more: 24v / 650W wind-solar hybrid regulator.
Is a battery input rated up to 60V compatible with a 24V wind regulator?
Not necessarily. The mention “up to 60 V” only indicates the maximum allowable input voltage; it does not confirm a nominal battery voltage of 24 V or compatibility with a wind regulator. The exact input voltage range, current, and allowable power, the type of source accepted, and the charging profile provided by the manufacturer must be checked. An input intended for solar panels or an energy station may reject a wind charge even if the voltage remains below 60 V. For a standard 24 V wind system, use a compatible 24 V nominal battery connected to the wind regulator according to its instructions. For an energy station, ask the manufacturer if there is an officially intended input or accessory for wind. Final compatibility must be verified on the exact references: nominal voltage, type of input or output, allowable power, regulation, and protections. Learn more: Wind regulators.
Conversion, wiring, and load shedding
Why has the role of inverters become essential?
Because they ensure the regulation/quality of energy injected in the era of decentralized production (wind, PV), while protecting the grid and users. Learn more: 230V wind grid-tie inverters.
Discharge resistor with an MPPT regulator: compatible?
A dump resistor only connects to an output and function explicitly provided by the regulator. A solar MPPT does not become a wind controller with an external resistor. Check the diagram, voltage, dissipation power, and protections on the exact references. Resources: Solar MPPTs · Wind regulators.
Can I connect a three-phase micro-hydro turbine (≈68V AC) to a "plug & play" 230V inverter?
Use a special wind/hydro injection inverter that directly accepts the 3-wire AC input from the generator; solar PV micro-inverters are not compatible. Check the input window (voltage/frequency) of the chosen inverter. Browse: 230 V injection inverters. Final compatibility must be verified on the exact references: nominal voltage, type of input or output, allowable power, regulation, and protections.
Which inverter to use for injecting the production of a three-phase wind turbine into 230V?
Use an inverter specifically designed for wind, compatible with the three phases of the generator, its voltage, and its power. A three-phase generator should not be connected to a standard solar inverter. Check the exact compatibility on the product sheet before any connection. Learn more: 230V wind grid-tie inverters.
Which wind inverters are compatible with a 24V 200W three-phase generator?
References 15495 and 15030 are mentioned in the source as options for a 24 V / 200 W generator, but voltage and power alone are not enough. Check the generator reference, its output, its voltage-speed curve, the current, and the braking or dump device. Only connect directly if the association is explicitly validated; a solar MPPT is not suitable. Learn more: 350W 24V wind grid-tie inverter.
Is a dedicated wind regulator needed if I already have solar MPPTs?
Yes, for a battery charging architecture: the wind turbine needs its compatible wind regulation, independent of the solar MPPTs. It must manage the charging and the planned braking or dumping. Another possibility is a direct injection set explicitly validated with its wind inverter; never connect the generator to a solar MPPT. Learn more: Hybrid kits for off-grid sites.
Is the connection order of the three wires of a wind generator important?
In general, no. The three wires correspond to the three phases of the generator's three-phase AC output: they do not have positive or negative polarity. Connect them only to the three-phase input of the compatible wind equipment indicated in the kit diagram. Do not connect the generator directly to a battery, a solar MPPT, or an inverter not designed for wind. A three-wire generator generally delivers three-phase AC: these conductors do not have positive or negative polarity. The connection must follow the instructions of the compatible regulator, rectifier, or inverter. Learn more: Wiring diagrams - solar and wind.
Can an additional load shedding path be added to a hybrid kit?
No. If the hybrid kit is not designed to receive an external load shedding path, do not add any resistance or additional output. The system must be used according to its original architecture. Any unplanned modification can disrupt regulation, battery charging, or kit protections. Final compatibility must be checked on exact references: nominal voltage, type of input or output, allowable power, regulation, and protections. Learn more: Wind + solar hybrid kits.
Can I use a wind-solar hybrid controller without a battery by sending all the energy to the discharge resistor?
No. A charge controller designed for a battery bank should not be used without a battery. The discharge resistor is only meant to dissipate excess energy according to the intended operation; it does not replace the battery needed for system stabilization and regulation. For a battery-less application, a specific architecture with suitable rectification and dissipation load must be designed, without diverting a controller intended for battery charging. Final compatibility must be checked on exact references: nominal voltage, type of input or output, allowable power, regulation, and protections. Learn more: Three-phase rectifier diode bridge.
What is the role of the charge controller (wind/solar)?
The controller manages charging according to the battery profile and source limits. On the wind side, it must also ensure or control the braking or load shedding planned by the system. The cut-off against deep discharge depends on the devices and wiring; it is not an automatic function of every controller. Resources: wind controllers · solar MPPTs.
What is the difference between a classic wind controller and a hybrid controller?
Classic: wind input only. Hybrid: wind + solar inputs (MPPT/PWM) for a combined system on the same battery. See: hybrid controllers.
Content, extension and accessories of the kits
Can the hybrid kit reference 15822 accommodate a generator?
Yes. On the hybrid kit reference 15822, a compatible generator can be connected to the AC INPUT 230 V mains input of the inverter. The generator must provide voltage, frequency, and power compatible with the limits indicated on the inverter's datasheet. Validate the connection and protections before use. Learn more: Solar hybrid kit 2580 Wc + vertical wind 2000 Wc - LiFePO4 Batteries 10.24 kWh - Inverter 5000 W MPPT 80 A.
Can you create a custom solar and wind kit with a Tulip for a house?
We do not conduct custom studies or create personalized kits integrating a Tulip. Consult the published kit compositions. The choice should be based on the wind at the future rotor, model curves, and desired architecture, rather than a general comparison between wind turbine shapes. Learn more: Self-consumption hybrid kits.
Can I add a second solar panel to the hybrid kit reference 15739?
Adding a second solar panel can be considered on kit reference 15739, provided the regulator's limits are respected: maximum solar power, input voltage, allowable current, and 12 V architecture. The additional panel should not be connected without verifying these characteristics on the kit and regulator datasheet. Final compatibility must be checked on exact references: nominal voltage, type of input or output, allowable power, regulation, and protections. Learn more: Wind + solar hybrid kits.
What renewable energy accessories do you offer?
Solar/wind regulators, converters, chargers, relays/contactors, meters, and measuring instruments. Category: solar equipment.
Can solar panels be added to the hybrid kit ref. 15824?
The extension is only possible within the published limits for reference 15824: PV power, open-circuit voltage, MPPT range, current, number of panels per string, and protection capacity. Do not rely on an old power value as a guarantee. Check the current datasheet and validate the wiring before adding modules. Learn more: Hybrid kits for isolated sites.
What does the solar and wind hybrid kit ref. 15824 include and is the mast included?
The exact content of reference 15824 must be checked on the product sheet at the time of order. Do not assume that the mast, batteries, cables, protections, or accessories are included if they are not explicitly listed. Also check the selected options and the cart, as the content of a kit may change. Learn more: Hybrid kits for remote sites.
Which battery and converter to choose with the hybrid kit reference 15739?
A 12 V / 100 Ah lithium battery can form a basis for this configuration, subject to compatibility with the regulator and its charging profile. To power devices at 230 V, use a pure sine wave converter 12 V to 230 V. Its continuous power and peak power should be chosen according to the connected devices and their starting currents. Learn more: 230V Converters (pure sine wave).
Need advice on a reference?
Specify the relevant references and the characteristics of your installation to customer service.